Timegrapher

Measures rate, amplitude and beat error — the instrument that makes regulation possible.

Regulate Testing & Regulation
Timegrapher — technical drawing

Specification

Measured valuesRate · amplitude · beat error
Rate resolution±1 s/day typical
Amplitude range180° – 360°
Beat error range0 – 9.9 ms
Supported frequencies18,000 – 36,000 vph
Lift angle setting30° – 52°, user entered
SensingAcoustic microphone or inductive clip
PositionsMeasured manually — one at a time

Technical parameters

ReferenceQuartz timebase
SamplingContinuous trace of tick intervals
Trace qualityOne clean line is the goal
NoiseAmbient sound and movement noise both interfere
CalibrationReference oscillator is the only standard
Use magnificationAvoid magnetismVentilate

Overview

A timegrapher listens to the watch through a microphone or a clip-on sensor and prints a trace of each tick, comparing them against a reference oscillator. From those intervals it derives the three numbers that matter: rate in seconds per day, amplitude in degrees, and beat error in milliseconds.

Lift angle has to be entered correctly or the amplitude reading is meaningless. Lift angle is a property of the escapement geometry, typically between 38° and 52° for a Swiss lever, and the timegrapher uses it to convert the time the balance spends in impulse into a rotation angle. Get it wrong and every amplitude figure is systematically wrong.

Beat error is the asymmetry between the two halves of an oscillation — how far off centre the impulse happens. It is set by the position of the hairspring stud relative to the impulse jewel, not by the regulator. A beat error above about 1 ms means the balance is being impulsed unevenly, and no rate adjustment will make that watch run well.

What matters about it

  • Reports rate, amplitude and beat error together
  • Lift angle must be entered to read amplitude correctly
  • Beat error is a mechanical fault, not a rate problem
  • Trace quality reveals knocking, rebanking and noise
  • Multi-position measurement is the real diagnostic
SafetyA timegrapher is electronic and low voltage, but it is still bench equipment used around solvents. Keep fluids away from the instrument, and do not open the case of the instrument while it is connected to mains power.

Practical notes

  • Look up the lift angle before measuring; guessing makes amplitude useless.
  • Measure in at least three positions — a single dial-up reading hides most faults.
  • Fix amplitude before rate, and beat error before either.
  • A noisy or doubled trace means a mechanical problem, not a bad instrument.

Compatible with

Mechanical movements of all beat ratesSwiss lever escapementsCoaxial escapementsVintage and modern movements